Planning and Environmental Documents for Public Review

Click here to view USACE Galveston District Planning and Environmental documents for public review.

Viewing & Comments

Viewing Notices: To view a full public notice or its associated drawings file (if any), click on either full public notice or permit drawings link in the attachments section. To download the file to your computer, right-click on the public notice or drawings link, then select "Save Target As" from the menu.

How to Send Comments on Regulatory Division Public Notices: Send comments to the Regulatory Division, U.S. Army Corps of Engineers, Galveston District, 2000 Fort Point Road, Galveston, Texas 77550 or by electronic mail to our Public Notice Comment Email. Comments made in reference to a public notice should include your name, address, phone number and the Department of the Army permit number referenced in the public notice (e.g. SWG-2015-00001).  

How to Send Comment on Other Galveston District Public Notices: Please follow the instructions included with the public notice. For Galveston District Planning and Environmental Documents for public review, please click here.

SWG-2013-00189 - City of Port Aransas - Nueces County

Published June 9, 2015
Expiration date: 7/10/2015

Full Public Notice    Project Plans    

The applicant proposes to develop FAA-compliant Runway Safety Areas (RSAs) on both Runway 12 and Runway 30, extend Runway 30 a distance of 681 feet to provide additional runway length for aircraft arrivals and departures, and develop a full length parallel taxiway.

Major components of the project include the following actions:

• Extend the existing 3,482-foot-long Runway 12/30 a distance of 681 feet to the southeast;

• Extend the parallel taxiway 1,921 feet to the Runway 12 end;

• Construct a connector taxiway to terminate at the northwest end of the runway;

• Clear and grade land a distance of 240 feet beyond the southeast end of the extended runway to develop an RSA in compliance with FAA design standards;

• Expand the terminal apron by 10,500 square yards;

• Relocate Outfall Ditch No. 9 as required for RSA development at the Runway 30 end of Runway 12/30;

• Displace the Runway 12 threshold and implement declared distances;

• Install Medium-Intensity Runway Lights (MIRLs) on the extended runway;

• Relocate the Runway 12 Precision Approach Path Indicators (PAPis);

• Install holding position signs;

• Apply reflective pavement markings;

• Install temporary and permanent erosion and sedimentation controls; and

• Implement mitigation measures for unavoidable wetland impacts associated with the proposed project. 

 The applicant states that the project will require the permanent placement of fill within 6.11 acres of wetlands, 0.10 acre of open waters adjacent to Corpus Christi Bay, and 484 linear feet of a manmade ditch.